Home/Products/Water Treatment Consumables/UV Disinfection Consumables

UV Disinfection Consumables

UV Lamps, Ballasts & Quartz Sleeves

UV lamps, electronic ballasts, quartz sleeves and UV sensors for low-pressure, TOC and medium-pressure UV systems. Parts are selected by equipment model, power, wavelength, dimensions and operating conditions.

Discuss Your Requirement
Range of KONCHE UV consumables: germicidal lamps, ballasts, quartz sleeves and UV sensors
KONCHEINDUSTRIAL WATER TREATMENT SYSTEMSMODEL KONCHE UC · UV CONSUMABLESREACTOR-MATCHEDDOSE SAFEREPLACEMENT PLANENGINEERED BY KONCHE · 2026
QUICK TECHNICAL ANSWER

What are UV Disinfection Consumables?

KONCHE UV consumables: genuine lamps, electronic ballasts, quartz sleeves and sensors for 254 nm disinfection and 185 nm TOC stages — stock-supplied with technical selection support.

What it delivers

  • Stable UV output — high 254 nm transmission keeps microbiological compliance reliable
  • Ballasts with full protection reduce flicker, power fluctuation and lamp failure
  • Stock supply with same-day dispatch cuts disinfection downtime

Why trust KONCHE

  • UV equipment manufactured since 1997 — consumables specified by the equipment builder
  • Selection support matches lamp power, length and cap type to your unit
  • Intensity test report provided after guided replacement

Where we stand out

What matters to youHow KONCHE delivers
Stable disinfectionHigh-transmission genuine lamps keep dose on target
Long lamp life8,000–10,000 h low-pressure; 8,000–10,000 h medium-pressure
Fit-all adaptationLow-pressure, TOC and medium-pressure units of any brand
Fast responseStock in Shenzhen with same-day dispatch
PRODUCT DOCUMENTATION

UV lamps, electronic ballasts, quartz sleeves and UV sensors for low-pressure, TOC and medium-pressure UV systems. Parts are selected by equipment model, power, wavelength, dimensions and operating conditions.

UV disinfection consumables are the replacement lamps, quartz sleeves, ballasts and seals that keep 254 nm and 185 nm UV systems at their validated dose. The KONCHE UV consumables programme supplies lamp-and-ballast power classes from 10 W to 1,000 W for 254 nm disinfection, 185+254 nm TOC stages and broad-spectrum medium-pressure duties. The range includes conventional low-pressure lamps (10–80 W), low-pressure high-output / amalgam lamps (50–1,000 W), medium-pressure lamps (200–1,000 W), TOC-degradation lamps, matching electronic ballasts (10–1,000 W with over-current, over-voltage, short-circuit and over-temperature protection), G10Q wired lamp holders, custom quartz sleeves and 254 nm intensity sensors. A 1,000 W rating alone does not define lamp pressure: both low-pressure amalgam and medium-pressure configurations are available, so every replacement is confirmed against spectrum, lamp current, starting mode, dimensions, cap and reactor model. All parts are selected for KONCHE and mainstream-brand UV equipment with technical selection support. Typical users: ultrapure-water systems, pharmaceutical GMP loops, food and beverage lines, municipal and school drinking water, electronics and PCB plants, and pools.

PRODUCT CATEGORIES

CategorySpecificationTypical application
Conventional low-pressure UV lamps10–80 W, 254 nmFlow-through low-pressure sterilizers
Low-pressure high-output / amalgam lamps50–1,000 W, 254 nm or 185+254 nmHigh-output disinfection and oxidation systems
Medium-pressure UV lamps200–1,000 W, broad-spectrum 200–400 nmCompact high-intensity and pool/process-water systems
TOC-degradation lamps185+254 nm dual bandTOC UV degradation units
Electronic ballasts10–1,000 W, lamp-matchedMatched power supply for the specified lamp technology
G10Q wired lamp holdersFour-pin ceramic holder with application-matched leadsWater-treatment germicidal lamp connection
Quartz sleevesCustom diameter, length and end configurationUV lamp isolation and protection in the reactor
UV sensors254 nm intensityOnline dose monitoring

PRODUCT DATA

PartReferenceTypical life / selection note
Conventional low-pressure lamp10–80 W, 254 nm8,000–10,000 hours
Low-pressure high-output / amalgam lamp50–1,000 W, 254 nm or 185+254 nmConfirmed against the selected lamp specification
Medium-pressure lamp200–1,000 W, 200–400 nm8,000–10,000 hours, subject to lamp and system
TOC lamp185 nm + 254 nm8,000–10,000 hours, subject to system
Electronic ballast10–1,000 W; matched by current, voltage and starting modeApproximately 3–5 years
G10Q wired lamp holderFour-pin ceramic connection; lead length and wiring matched to equipmentInspect during every lamp replacement
Quartz sleeveMatched by outside diameter, length, wall thickness and end formApproximately 2–3 years
UV sensor / probeMatched to controllerAccording to calibration and condition

APPLICATIONS

IndustryWater pointSystem value
Pure / ultrapure waterTOC lamp replacementKeeps TOC on specification at the loop end.
PharmaceuticalsGMP purified-water loopsCompliant flow-through UV lamps.
Food and beverageProcess waterLamps and ballasts to food-safety standard.
Municipal / school waterDirect drinking stationsLow-pressure lamps protecting drinking safety.
Electronics / PCBChip cleaning waterTOC lamps meeting cleaning requirements.
PoolsCirculating waterMedium-pressure lamps, strong kill with fewer chloramines.

REPLACEMENT CYCLES

ConsumableRecommended cycleReplacement criterion
Low-pressure UV lamps8,000–10,000 hIntensity below 70% of initial
Medium-pressure UV lamps8,000–10,000 hIntensity drop or lamp blackening
TOC-degradation lamps8,000–10,000 hTOC removal efficiency decline
Electronic ballasts3–5 yearsFlicker, no-light or unstable power
Quartz sleeves2–3 yearsFouling or scaling reducing transmission

SUPPLY & SERVICE

AdvantageCustomer benefit
Stable UV outputHigh 254 nm transmission keeps microbiological results reliable.
Smooth ballast operationStable drive reduces flicker and power fluctuation, extending lamp life.
Complete range, wide fitCovers flow-through, TOC and medium-pressure units of any brand.
Stock with fast responseSame-day dispatch reduces disinfection downtime.
Technical selection supportMatched to equipment model and power requirements.
Fewer equipment faultsGenuine matched parts cut accessory-related failures.

FAQ

How do I order the correct UV lamp?

Send the system model, lamp marking, power, wavelength and a photo of the existing lamp or nameplate.

Why does the lamp still light but need replacement?

UV output can fall even when visible light remains. Replacement should follow operating hours and intensity monitoring.

How often should quartz sleeves be cleaned?

A common reference is every three months, adjusted for water hardness, iron, turbidity and deposits.

Can one ballast be used for different lamps?

Only when power, current, starting mode, dimensions and controller compatibility are confirmed. Do not assume interchangeability.

WHY KONCHE

01

Nearly 30 years of UV expertise

Since 1997, Konche has built UV disinfection equipment and supplied its consumables — lamps, ballasts and sleeves specified from the equipment builder perspective.

02

Professional customization

Each system is designed around the water analysis, industry standard, site condition, capacity and final use.

03

Controlled system quality

Component selection, factory testing, water-quality verification and process control are managed as one complete system.

04

Full-cycle technical service

KONCHE supports proposal alignment, technical documentation, consumables supply, maintenance guidance and remote operational clarification.

PROJECT INQUIRY

Tell us about
your water.

Send your water analysis, target capacity and application. Konche will help select and configure the suitable system.

Get Expert Support