Complete Solution Portfolio
7industry solution paths connect the project challenge with a practical equipment combination and a defined treatment objective — plus country-specific market guides written for local buyers.
Engineering reference only — the final process train is configured against verified project inputs.
Industrial Pure Water & Ultrapure Water Solution

Overview
KONCHE engineers integrated pure and ultrapure water systems around feed-water quality, production capacity and the required conductivity or resistivity. The treatment train can combine pretreatment, RO, EDI, polishing, UV and point-of-use control.
Application Scenarios
- Electronics and semiconductor manufacturing
- Photovoltaic and new-energy production
- Biopharmaceutical and fine-chemical plants
- Industrial laboratories and quality control
Main Pain Points
- Water excursions surface as rejects and rework before anyone suspects the water.
- Feed-water drift makes a fixed specification hard to hold week after week.
- One plant must feed several points of use at different grades.
How KONCHE Responds
- Online conductivity monitoring with alarms catches drift before it reaches your process.
- Branded RO membranes (e.g., Dow, Hydranautics) and EDI polish configured to your analysis hold the spec at the point of use.
- Modular trains supply different purified-water grades to different lines from one system.
Recommended Equipment
Treatment Outcomes
- Stable conductivity or resistivity at the specified duty.
- Consistent water quality supports production yield and repeatability.
- Point-of-use control protects high-specification processes.
Electronics & Precision Manufacturing Ultrapure Water Solution

Overview
KONCHE configures electronic-grade ultrapure water trains for semiconductor, PCB, display, photovoltaic and battery manufacturing. Pretreatment, RO, EDI and 185/254 nm UV polishing are integrated with storage and a circulating distribution loop.
Application Scenarios
- Semiconductor packaging and precision electronics
- PCB etching, rinsing and plating
- Display and photovoltaic manufacturing
- Battery and new-energy material plants
Main Pain Points
- Trace ions and particles land directly on yield — and on customer audits.
- TOC and microbial growth quietly degrade water sitting in tanks and loops.
- Regeneration stops on ion-exchange plants take your ultrapure supply down with them.
How KONCHE Responds
- Double-pass RO with first-tier membranes (e.g., Dow, Hydranautics) + EDI holds up to 18.2 MΩ·cm at the point of use.
- 185/254 nm UV polishing and a circulating loop keep TOC as low as ≤0.5 μg/L through storage and distribution.
- EDI regenerates electrically — no acid, no caustic, no regeneration stops — while PLC monitoring alarms drift before it reaches your line.
Recommended Equipment
Treatment Outcomes
- Designed for product water up to 18.2 MΩ·cm.
- TOC can be controlled to 0.5 μg/L at the designed duty.
- Continuous EDI and a UV-protected loop maintain point-of-use quality.
Seawater & Brackish Water Desalination Solution

Overview
KONCHE configures seawater and brackish-water desalination systems for high-salinity sources, remote locations and projects with limited infrastructure. Skid-mounted or containerized plants integrate pretreatment, high-pressure RO, post-treatment and UV disinfection.
Application Scenarios
- Middle East desalination and industrial supply
- Islands, coastal mining and remote facilities
- Field camps and temporary project sites
- Rapid-deployment water supply projects
Main Pain Points
- High-salinity feed corrodes and scales ordinary equipment into early retirement.
- Remote sites cannot count on local civil works or service coverage.
- Untreated saline water is unusable for process, drinking or irrigation.
How KONCHE Responds
- Corrosion-conscious builds — 316L wetted parts, FRP/PP vessels, anti-corrosion frames — for hot, humid and saline sites.
- Containerized plants arrive factory-assembled: destination work is unload, connect, start.
- High-pressure RO trains convert saline feed to the agreed specification, sized from your analysis.
Recommended Equipment
Treatment Outcomes
- Saline feed is converted to the agreed project-water specification.
- Containerized delivery reduces destination setup and deployment time.
- Modular scope adapts to remote and infrastructure-limited locations.
Drinking Water Purification & Community Water-Supply Solution

Overview
KONCHE provides centralized drinking-water purification systems for communities, institutions and commercial projects. Selection follows raw-water turbidity, salinity, microbiological risk, output and the applicable drinking-water standard, with maintainability prioritized for overseas sites.
Application Scenarios
- Village and community projects in Africa and Southeast Asia
- Mining and construction camps
- Schools, hotels and public facilities
- Commercial drinking-water supply
Main Pain Points
- A failed water test can close a refilling station or school connection overnight.
- Sediment-heavy or iron-rich sources wear out filters and budgets.
- Remote sites need equipment that local staff can actually run.
How KONCHE Responds
- Multi-barrier trains configured to PNSDW parameter targets — final compliance verified by local DOH testing.
- 316/316L stainless contact parts and media + UF stages selected for your source water, not a generic model.
- PLC one-button operation plus 72-hr spare-parts dispatch keeps downtime short where service coverage is thin.
Recommended Equipment
Treatment Outcomes
- Sediment, colloids and microbial risk are reduced through a configured barrier train.
- Product water is designed around the applicable drinking-water standard.
- Maintainable operation supports reliable centralized supply.
Food & Beverage Water Treatment Solution

Overview
KONCHE configures process-water systems for beverage, brewing and food production around hardness, microbiological control, product quality and cleaning requirements. RO, UF and UV stages are selected to protect consistency and hygienic operation.
Application Scenarios
- Bottled water and beverage production
- Breweries and fermentation lines
- Food and ingredient processing
- Process-water and cleaning-water supply
Main Pain Points
- Off-spec hardness and scaling interrupt bottling and shorten CIP cycles.
- One microbial excursion puts a production batch — and a customer — at risk.
- Seasonal feed-water swings make a repeatable formulation hard to hold.
How KONCHE Responds
- Softening + RO sized from your water analysis keep hardness and TDS stable through peak season.
- UV + ozone loop sterilization on 304/316L contact parts protects microbiological results without chemical by-products.
- PLC-monitored trains with online conductivity and alarms flag drift before it reaches the filler.
Recommended Equipment
Treatment Outcomes
- Lower hardness and dissolved solids support stable production.
- UV disinfection provides chemical-free microbial control.
- Configured water quality supports process and cleaning duties.
Industrial UF Pretreatment Solution

Overview
KONCHE uses ultrafiltration as a stable membrane barrier for industrial source water and reuse projects. UF removes suspended solids, fine particles and colloids before downstream RO, helping stabilize feed quality and reduce fouling pressure.
Application Scenarios
- Factory raw-water pretreatment
- Mining and process-water clarification
- RO membrane pretreatment
- Industrial water reuse front end
Main Pain Points
- Every unplanned RO cleaning stop is production you did not schedule.
- Cartridge-only pretreatment turns variable turbidity into a standing consumables order.
- Seasonal source swings destabilize media-only trains.
How KONCHE Responds
- 0.01 μm PVDF hollow-fiber UF ahead of RO protects membranes and can extend cleaning intervals.
- Automatic backwash and air scouring cut manual intervention and cartridge spend.
- 2–5-year typical membrane service life keeps operating cost predictable.
Recommended Equipment
Treatment Outcomes
- UF intercepts suspended solids and colloidal load.
- More stable RO feed protects membranes and recovery performance.
- Reduced fouling pressure lowers cleaning and consumable demand.
Laboratory Water Treatment Total Solution

Overview
KONCHE configures laboratory water systems around feed-water quality, daily demand, instrument sensitivity and test methods. Purification, UV treatment and point-of-use dispensing can provide multiple grades for washing, reagent preparation and high-precision analysis.
Application Scenarios
- University and research laboratories
- Analytical testing and instrument rooms
- Biopharmaceutical R&D
- Quality control and precision testing
Main Pain Points
- Poor water shows up as bad baselines, failed blanks and repeated runs.
- One grade never fits every method in the lab.
- Quality drift between cartridge changes quietly skews results.
How KONCHE Responds
- Type I water at 18.2 MΩ·cm, TOC ≤5 ppb protects HPLC, ICP and IC results.
- Dual-grade output — ultrapure and pure water from one benchtop unit.
- Cartridge-life tracking with alerts replaces guesswork with scheduled changes.
Recommended Equipment
Treatment Outcomes
- Multiple grades support washing, reagent and analytical workflows.
- Systems can deliver ultrapure water up to 18.2 MΩ·cm.
- Stable water quality improves testing repeatability and instrument protection.