Home/Products/UV Water Sterilizer/Medium-Pressure UV Disinfection System

Medium-Pressure UV Disinfection System

Broad-Spectrum UV for Large-Flow Disinfection & Reuse

2–10 kW · 200–400 nm · 1–500 m³/h

2–10 kW
Lamp power
200–400 nm
Spectrum
1–500 m³/h
Capacity
  • Factory-Direct Manufacturer · Since 1997
  • One Lamp Replaces Dozens
  • Broad-Spectrum 200–400 nm
  • Covers Cryptosporidium
  • ≥40 mJ/cm² Dose Monitoring
  • Water- or Air-Cooled
1-Year Warranty & Consumables Terms ▾
1-year whole-machine warranty from commissioning. Exclusions: membranes, UV lamps, filter cartridges and other consumables. First-tier brand membranes and components (e.g., Dow, Hydranautics) and control configuration are selected for your feed-water scenario and quality targets.
KONCHE medium pressure UV disinfection system with 2 to 10 kW broad-spectrum lamps
KONCHEINDUSTRIAL WATER TREATMENT SYSTEMSMODEL KONCHE MUV · MEDIUM-PRESSURE UVBROAD SPECTRUMHIGH INTENSITYUVT-SIZEDENGINEERED BY KONCHE · 2026
PRODUCT DOCUMENTATION

High-intensity broad-spectrum 200–400 nm UV for large-flow disinfection. One lamp is typically 2–10 kW, with ordinary-water flow from 1 to 500 m³/h and pure-water flow from 5 to 200 m³/h according to UV transmittance, dose and system configuration.

KONCHE medium-pressure systems run single 2–10 kW lamps covering 1–500 m³/h on ordinary water (5–200 m³/h on pure water) with up to 99.99% inactivation, water-jacket or air cooling, and UV-dose monitoring to ≥40 mJ/cm². Lamp life is 5,000–8,000 h; feed requirements are turbidity below 5 NTU and suspended solids below 5 mg/L. Typical projects: high-flow purified-water lines, food and beverage CIP water, pools and water parks, municipal supply and reuse, aquaculture.

CORE BENEFITS

AdvantageCustomer benefit
Large-flow capacityOne lamp replaces dozens of low-pressure lamps — compact and efficient.
Broad-spectrum killMulti-target 200–400 nm output, effective on resistant organisms.
Space compactSmall footprint, friendly to retrofit projects.
Fewer maintenance pointsLower lamp-replacement workload, annual cost and downtime.
Multi-scenario fitPure water, food, pools, municipal and aquaculture duties.

TECHNICAL DATA

Full technical data
ParameterValue
WavelengthBroad spectrum 200–400 nm
Lamp power2–10 kW per lamp
Ordinary-water flow1–500 m³/h
Pure-water flow5–200 m³/h
Lamp life5,000–8,000 hours
Chamber316L stainless steel
Pressure≤0.6 MPa
Lamp quantity1–4 lamps
Drinking-water dose reference≥40 mJ/cm²

MODEL RANGE

ModelLampCapacityTypical application
KC-MUV-2K2 kW × 11–30 m³/hMid-to-large purified-water lines, food processing
KC-MUV-4K4 kW × 130–100 m³/hHigh-flow pure water, pool circulation
KC-MUV-10K10 kW × 1100–300 m³/hMunicipal supply, industrial circulating water
KC-MUV-20K10 kW × 2300–500 m³/hLarge municipal and EPC projects (custom)

Note: capacities and configurations can be customized to actual project requirements.

ADVANCED PHOTO-OXIDATION — ENGINEERED TO ORDER

Beyond disinfection, the same medium-pressure platform is engineered into TiO₂ photocatalytic photo-oxidation packages for difficult industrial effluents. Broad-band UV acting on the titanium-dioxide catalytic chamber generates hydroxyl radicals, breaking refractory organic molecules into smaller, readily degradable compounds — or fully to CO₂ and H₂O.

DutyHow the photo-oxidation package is applied
Refractory COD reduction1–30 kW baffled-reactor packages raise biodegradability ahead of biological treatment or polishing.
Color and odor removalDye-containing, chemical and pulp effluents are oxidized for color and odor control.
Landfill leachate pretreatmentHigh-strength leachate is cracked to reduce the downstream treatment load.
Operating reliabilityAutomatic quartz-sleeve wiping, full PLC control and dose monitoring as standard.

Photo-oxidation packages are engineered to order against a verified water analysis and treatment target; stated values are reference ranges, not project guarantees.

APPLICATIONS

IndustryWater pointSystem value
High-flow pure-water linesPost-RO disinfectionSingle high-power lamp replaces dozens of low-pressure lamps.
Food and beverageProcess and CIP waterBroad-spectrum kill, no chemical residues, food-safety compliant.
Pools and water parksCirculating waterInactivates chlorine-resistant organisms; reduces chloramines.
Municipal supply / reusePlant outlet, reclaimed waterLarge-flow disinfection without by-products, replacing chlorination.
AquacultureRecirculating culture waterBroad-spectrum disease control without changing water chemistry.
Textile, chemical and pulp effluentsRefractory COD, color and odorEngineered photo-oxidation packages (see above) reduce load where biology alone struggles.

FAQ

What is the difference from low-pressure UV?

Medium-pressure UV uses higher power and a broader spectrum for compact high-flow duty; low-pressure UV is more energy-efficient for many ordinary flows.

How is cooling selected?

Water-jacket cooling or air cooling is selected according to lamp power, water temperature, installation and maintenance conditions.

How long does the lamp last?

Typical lamp life is 5,000–8,000 operating hours, subject to water quality, power cycling and cooling.

What information is needed for selection?

Flow rate, UV transmittance, target dose, water temperature, installation space and pressure are required.

How do you size a medium-pressure UV system?

Size to about 1.2 times the peak flow, verify UV transmittance — pre-filtration is recommended below 85% — and keep feed turbidity below 5 NTU and suspended solids below 5 mg/L.

Can medium-pressure UV reduce refractory COD, color or odor?

Yes. KONCHE engineers UV photocatalytic TiO₂ (titanium-dioxide) photo-oxidation packages — 1–30 kW baffled reactors with automatic quartz-sleeve wiping — as customized systems for refractory wastewater duties.

WHY KONCHE

01

Nearly 30 years of expertise

Since 1997, KONCHE has applied high-intensity medium-pressure UV to large-flow duties — 2–10 kW single-lamp packages with dose and cooling engineered per stream.

02

Professional customization

Each system is designed around the water analysis, industry standard, site condition, capacity and final use.

03

Controlled system quality

Component selection, factory testing, water-quality verification and process control are managed as one complete system.

04

Full-cycle technical service

KONCHE supports proposal alignment, technical documentation, consumables supply, maintenance guidance and remote operational clarification.

PROJECT INQUIRY

Tell us about
your water.

Send your water analysis, target capacity and application. KONCHE will help select and configure the suitable system.

Get Expert Support →