KONCHE project case studies
Each case records the water duty, site constraints, equipment configuration, engineering approach and evidence status so an engineer can compare the design basis with their own project. New cases are added as project evidence is documented.
A university campus project treating variable roof rainwater (CODcr up to 100 mg/L) to a national drinking-water standard with fiber filtration, activated carbon, UF, RO and UV disinfection.
Read the project design HEALTHCARE PURE WATER · DOUBLE-PASS RO + EDI · CHINA Double-pass RO and EDI pure water for a community healthcare centerAn accepted project serving dental, endoscopy and laboratory departments: at least 1.5 tonnes/h in total, including a 300 L/h laboratory allocation.
Read the case 35,000 TPD · OPEN-CHANNEL UV · CHINA 35,000 Tonnes per Day Open Channel UV Wastewater Project in ChinaExplore KONCHE's accepted 35,000-tonne-per-day wastewater UV project in China, with 17.92 kW equipment sets, 56 lamps per set and channel specifications.
Read the case 3,500 TPD · DOMESTIC WASTEWATER · CHINA 3500 TPD Domestic Wastewater UV Disinfection Case in ChinaExplore a commissioned KONCHE domestic wastewater UV project in China with 3.84 kW lamp power, PLC controls and Class I A discharge acceptance.
Read the case 5,000 TPD · CLEANING & MONITORING · CHINA 5,000 TPD Wastewater UV Disinfection System with Cleaning and MonitoringExplore a commissioned 5,000 TPD wastewater UV project in China with 316 stainless steel modules, pneumatic cleaning components and operating-condition monitoring.
Read the case 5,000 TPD · CHANNEL INTEGRATION · CHINA 5,000 TPD Open-Channel Wastewater UV Project with 0.8 m Effective Water DepthSee a commissioned 5,000 TPD open-channel wastewater UV project with a 5.12 kW lamp configuration, 0.8 m effective water depth and defined channel dimensions.
Read the case PROJECT DESIGN · BRACKISH-WATER RO · EGYPT 1,000 LPH brackish-water RO system for saline, hard well waterAn anonymized project design covering media filtration, automatic softening, single-pass BWRO, final UV treatment, equipment specifications and quotation factors.
Read the project design OPEN-CHANNEL UV DISINFECTION · SOUTH CHINA Two-plant municipal wastewater project — 5,000 + 15,000 m³/dA delivered China reference with 76 × 320 W lamps, pneumatic sleeve wiping and PLC/HMI control, plus engineering guidance for international EPC adaptation.
Read the case MEDIUM-PRESSURE UV · HOTEL POOL 2025 hotel pool — 1.8 kW medium-pressure UV, 100–120 m³/hEquipment-supply and factory-test record for a 600 m³ hotel pool: KCM-UV1.8KW on the recirculation line, five-to-six-hour theoretical turnover, with the validation limits stated plainly.
Tell us about
your water.
Send your flow rate, water-quality data and target standard for UV disinfection sizing and a quotation.
Request a Project Quote ↗